Oak & Carter

WO 49018 · wireline

Auto-cleared
Work order
49018
Site
Oak & Carter
Line
wireline
Photographs
10
On site
28 min
Received
10/19, 17:33 UTC
Capture chain
Intact
Device
00000003…

Location against the assigned run

placard — 8 m off the runbefore — 1 m off the runhandhole — 8 m off the runconduit — 17 m off the rundepth — 15 m off the runconcrete-pad — 12 m off the runpole — 9 m off the runtree-trim — 11 m off the runscale — 9 m off the runafter — 9 m off the run50 m
on the assigned run the phone sent him back beyond toleranceMaple & 3rd — run 03 · tolerance 60 m
Judge the workEvery other check on this page is about the photograph. This one is about what the photograph shows — read against the failure mode the requirement exists to catch. It recommends; it never clears.

On the ground2

Job placard
Job placard
focus
2876
light
131
off run
8m
at
07:11
Before you started
Before you started
focus
3254
light
102
off run
1m
at
07:15

At the trench7

Handhole
Handhole
focus
1793
light
128
off run
8m
at
07:18
Conduit in the ground
Conduit in the ground
focus
3327
light
139
off run
17m
at
07:22
Buried cable depth
Buried cable depth
focus
1243
light
141
off run
15m
at
07:24
Concrete pad
Concrete pad
focus
2696
light
132
off run
12m
at
07:28
Pole
Pole
focus
1711
light
83
off run
9m
at
07:30
Tree trimming
Tree trimming
focus
1770
light
109
off run
11m
at
07:33
Distance and scale
Distance and scale
focus
2096
light
88
off run
9m
at
07:36

Before you leave1

Site put back
Site put back
focus
2234
light
82
off run
9m
at
07:39

The shot list behind this package is our best reading of AT&T’s requirements, not their published spec.